Affichage des articles dont le libellé est No Power at Thermostat. Afficher tous les articles
Affichage des articles dont le libellé est No Power at Thermostat. Afficher tous les articles

jeudi 12 mars 2015

No Power at Thermostat

We just moved and I'm dealing with a 20 year old American Standard heat pump. Everything worked peachy for about 2 weeks and then then my Nest thermostat said it wasn't getting power. So I checked the voltage on Rh and sure enough no voltage. I went down to the air handler and pulled the fuse on the 24 volt transformer and it was blown, so I bought more odd ball fuses online and plug one in and still nothing. I opened the box only to find they have taken the factory fuse out of line and installed a 5A automotive fuse, and that fuse is not blown. So I get out my multimeter and check the voltage running to the transformer. It tested around 120V, but on the output side before the fuse no voltage. So I assume I have a bad transformer. The thing that gives me pause is that the sticker on the transformer says "Pri: 60Hz WHT-COM, DRM-200V, RED - 230V, SEC 24V, 75VA". This makes it sound to me like I should be getting 220V at the transformer primary? I have no idea what kind of failure could occur to have me 110V instead of 220V? Or it is the wrong transformer? Am I missing something here. The air handler is an American Standard TWE065E130A0. Is there anyone that can help me trouble shoot this?